The physical inventory manager (PIM): 1. Organize a preparatory meeting with the operational team to:
2. Notify affected parties providing adequate lead time to plan appropriately:
3. Prepare the storage area:
|
It requires that: 1. No inventory movements (receptions, shipments or transfers) may be recorded in the inventory register during the physical count of the warehouse, in case of full inventory counts:
2. Any items shipped and not picked up or receipt that come in, are segregated and labelled “do not inventory” 3. Blind counts are performed: The physical inventory is made without the knowledge of the quantity in the inventory records
4. Each count team has an assigned zone to count
5. At the end of, and during the inventory count process, the PIM and if possible the FRA walk through the warehouse and visually inspect that a count tag is attached to every inventory item to check that all inventory items have been counted and also ensure that the inventory is not counted twice 6. Exemptions for counts must be justified by cost savings, e.g. off-site locations; however, they have to be evidenced by a confirmation letter (including inventory date, list of products of the count, stock location, type of count ( meter reading,...), the name of the person in charge and his signature) 7. Cycle counts can be split by storage location or bins, in case of counts using WM Module;
|
|