Purpose
The purpose of this document is to define the conversion approach to create Measurement Document in S/4 HANA.
Measurement documents are used to record measurement readings on the condition of an equipment e.g. temperature. It is also used to record counter readings of an equipment e.g. Engine Running hours. These counter readings will be the trigger for maintenance plan to initiate maintenance and/or inspection work.
Conversion Scope
The scope of this document covers the approach for converting active Measurement Document from Legacy Source Systems into S/4HANA.
At Syensqo, Measurement Documents are created for Measuring Points to monitor the condition and usage of assets. They provide critical input to support condition-based and usage-based maintenance strategies. Measuring Points are created on either Functional Locations or Equipment, depending on the asset structure and monitoring requirements. The Measurement Documents are also a core component of Asset Performance Management (APM) used to monitor asset health, detect trends, and trigger condition-based or predictive maintenance actions.
The approach is to migrate the last Measurement Document for each active Measuring Point which is driving the active Maintenance Plans and Items in order to start the Maintenance Plan in S/4 HANA with the objective to continue with the cycle. For Measurement Documents related to APM, up to three years of historical data will be migrated from legacy systems to ensure seamless continuity in asset monitoring, trend analysis, and maintenance decision-making within the S/4 HANA.
Note: Digital Local Indicators (eg Sensor Data available in Startek) are not in scope for migration as these will be mass created via Custom Development Program (ERP-582)
The data from legacy system includes:
- (Counter Plan related) Latest Measurement Document Reading for active (IMPTT-INACT<>"X") Measuring Point that is a counter (IMPTT-INDCT) and linked to an active Maintenance Plan (MMPT-POINT) and linked to Functional Location /Equipment assigned to relevant plant in scope
- Active Maintenance Plan is when the System Status (TJ02T-TXT04) is not "DLFL"
- For the relevant plants in scope, refer to Value Mapping: Plant (Maintenance Plant = Yes) (IFLOT-IWERK /EQUI-IWERK)
- (APM Related) Measurement Documents for active (IMPTT-INACT<>"X") Measuring Points (IMPTT-MPOBJ) for Functional Locations and Equipment for the past 3 years (IMRG-IDATE), limited to:
</Start CR0282>
- Legacy Functional Location listed in the report [Equipment related to APM] or [Functional Location related to APM]
- Legacy Equipment listged in the report [Equipment related to APM]
specific Technical Object Types (EQUI-EQART/IFLOT-EQART) based on Value Mapping: OTH_Technical Object Type_APMspecific plant (EQUI-IWERK/IFLOT-IWERK) based on Value Mapping: OTH_Plant_APM
</End CR0282>
The data from legacy system excludes:
- Measuring Documents with reversal indicator (IMRG-CANCL)
- Long Text for Measurement Document
List of Tables to extract for this object is maintained here: Extract Table Register.
Illustration of relevant Measurement Document for extraction (Point 1 of relevancy criteria):
| Measuring Point | Measurement Document | Date | Time | Counter Reading | Reversal Indicator |
|---|---|---|---|---|---|
| A1 | 001 | 23 Feb 2026 | 10 am | 2010 | |
| A1 | 002 | 1 Mar 2026 | 2 am | 2040 | |
| A1 | 003 | 1 Mar 2026 | 4 am | 2050 | |
| A1 | 004 | 25 Feb 2026 | 5 pm | 2020 | |
| A1 | 005 | 2 Mar 2026 | 3 pm | 2060 | X |
| A1 | 006 | 26 Feb 2026 | 4 pm | 2021 | X |
Based on the above sample data, the following scenario and conclusion apply:
| Scenario | Conclusion | Rationale |
|---|---|---|
| 1 | Measurement Document 003 is to be extracted | Latest Counter Reading without reversal indicator |
List of source systems and approximate number of records
| Source | Scope | Source Approx No. of Records | Target System | Target Approx No. of Records |
|---|---|---|---|---|
| DCT | Measurement Documents will be collected via DCT. An initial extract of the relevant Measurement Documents will be provided in google sheet format to assist business in decision making on including any relevant Measurement Documents from PF2 and WP2 as Measurement Documents in S/4 HANA. Any additional Measurement Documents that need to be created to support the new design may be added in the DCT. Please see an indication of what will be baselined from source systems below and what will be constructed in the DCT. Note: The decision to implement DCT only for Measuring Point and Measurement Document was based on the current business usage in SAP. The business has primarily been collecting relevant data outside of SAP. Additionally, it is not part of the current business process to create these Measuring Points and Measurement Documents in the system. Given that these two objects are not actively utilized and there are only a handful of Counter Based Maintenance Plans involved, the effort required to build the ETL process would not be justified at this time. | 5,000 | S/4HANA | 5,000 |
| DCT | Measurement Documents for plants which do not have data existing from PF2 and PF2 | TBD | S/4HANA | TBD |
Additional Information
Multi-language Requirement
Measurement document does not have multi language support. Measurement document text will be migrated using EN logon.
Document Management
Not Applicable
Legal Requirement
Not Applicable
Special Requirements
Not Applicable
Target Design
The technical design of the target for this conversion approach.
| Table | Field | Data Element | Field Description | Data Type | Length | Requirement |
|---|---|---|---|---|---|---|
| IMRG | MDOCM | IMRC_MDOCM | Measurement Document | CHAR | 20 | Internal Number |
| IMRG | POINT | IMRC_POINT | Measuring Point | CHAR | 12 | Mandatory |
| IMRG | IDATE | IMRC_IDATE | Date of the Measurement | DATS | 8 | Mandatory |
| IMRG | ITIME | IMRC_ITIME | Time of Measurement | TIMS | 6 | Mandatory |
| IMRG | MDTXT | IMRC_MDTXT | Measurement Document Text | CHAR | 40 | Conditional |
| IMRG | REDCV | IMRC_RECDV | Measurement Reading in Unit of Entry | FLTP | 16 | Conditional |
| IMRG | READG | IMRC_READG | Measurement Reading/Total Counter Reading in SI Unit | FLTP | 16 | Conditional |
| IMRG | VLCOD | IMRC_VLCOD | Valuation Code | CHAR | 4 | Conditional |
| IMRG | READR | IMRC_READR | Person who Took the Measurement Reading | CHAR | 12 | Mandatory |
Data Cleansing
| ID | Criticality | Error Message/Report Description | Rule | Output | Source System |
|---|---|---|---|---|---|
Not Applicable |
Note: List of Cleansing is maintained here: Conversion Specs Register (DCT & Cleansing Report)
Conversion Process
The high-level process is represented by the diagram below:
Collection will be done manually in the Data Collection Template for the following scenarios:
- For sites not on SAP-PF2 or WP2 systems
- For Measurement Documents that need to be created to support the to-be design
Data Privacy and Sensitivity
Not Applicable.Extraction
Extract data from a source into Advanced Data Migration and Management (ADMM). There are 2 possibilities:
- The data exists. ADMM connects to the source and loads the data into ADMM . There are 3 methods:
- Perform full data extraction from relevant tables in the source system(s).
- Perform extraction through the application layer.
- Only if ADMM cannot connect to the source, data is loaded to the repository from the provided source system extract/report.
- The data does not exist (or cannot be converted from its current state). The data is manually collected by the business directly in ADMM . This is to be conducted using DCT (Data Collection Template) in ADMM
The agreed Relevancy criteria is applied to the extracted records as reference point to identify the records that are applicable for the data construction in the DCT.
Extraction Run Sheet
| Req # | Requirement Description | Team Responsible |
|---|---|---|
| 1 | Extract data from source system based on relevancy rule | SyWay Data Team |
| 2 | Google Sheet report pre-populated with PF2 and WP2 information to be generated based on relevancy criteria. | SyWay Data Team |
Selection Screen
| Selection Ref Screen | Parameter Name | Selection Type | Requirement | Value to be entered/set |
|---|---|---|---|---|
| Not Applicable |
Data Collection Template (DCT)
Target Ready Data Collection Template will be created for Measurement Document data with exception of some fields which require transformation as mentioned in the transformation rule.
Delta Data Management: Initial collection will be done via the report and one-time load to the DCT will be performed. Any delta after the initial collection within the DCT will require business to take due diligence to ensure any subsequent delta cleansing is verified and aligned within the DCT.
Note: All rules specified below should be documented as a tooltip in the DC Page.
Format:
- Line 1: Mandatory / Conditional
- Line 2: Remaining text
Measurement Document Data Construction Rules
| Field Name | Field Description | Rule |
|---|---|---|
| ZPLANT | Plant | Mandatory Populate the Maintenance Plant of the FL/EQ linked to the Measuring Point. |
| ZLEGACYMDOCM | Legacy Measurement Document | Mandatory Must be unique. This is the key |
| ZLEGACYPOINT | Legacy Measuring Point | Mandatory Must be an existing legacy Measuring Point in Measuring Point DCT |
| IDATE | Date of the Measurement | Mandatory Valid Date within the past 1 year Date Format DDMMYYYY |
| ITIME | Time of Measurement | Mandatory Valid Time Time Format HHMMSS |
| MDTXT | Measurement Document Text | Conditional Populate if information exists |
| RECDV | Measurement Reading in Unit of Entry | Conditional Cannot be 0 If Measuring Point is a Counter: Mandatory and cannot be greater than Counter Over Reading of Measuring Point If Measuring Point is NOT a Counter: Must be between Upper and Lower Measurement Range Limit of Measuring Point. Only can be blank if "Indicator: Valuation Code Sufficient for Measurmnt. Document" of Measuring Point is checked |
| ZREADG | Total Counter Reading in Unit of Entry | Conditional If Measuring Point is NOT a Counter: Leave blank If Measuring Point is a Counter:
|
| VLCOD | Valuation Code | Conditional Only populate when Measuring Point has Code Group maintained. Must be blank otherwise. Must exist in Catalog Code DCT for Catalog Code Group of Measuring Point. |
Note: List of DCTs is maintained here: Conversion Specs Register (DCT & Cleansing Report)
Extraction Dependencies
| Item # | Step Description | Team Responsible |
|---|---|---|
Not Applicable |
Transformation
The Target fields are mapped to the applicable Legacy field that will be its source, this is a 3-way activity involving the Business, Functional team and Data team. This identifies the transformation activity required to allow ADMM to make the data Target ready:
- Perform value mapping and data transformation rules.
- Legacy values are mapped to the to-be values (this could include a default value)
- Values are transformed according to the rules defined in ADMM
- Prepare target-ready data in the structure and format that is required for loading via prescribed Load Tool. This step also produces the load data ready for business to perform Pre-load Data Validation
Transformation Run Sheet
| Item # | Step Description | Team Responsible |
|---|---|---|
1 | Obtain DCT Sign-off from Business. | SyWay Data Team |
2 | In dspMigrate, select the wave – S4/HANA – Plant Maintenance | Syniti |
3 | Go to Process Area Launch and Process the Object – Measurement Document | Syniti |
4 | Review and Validate Error and Preload Reports | Syniti |
5 | Execute the transformation to prepare the target tables | Syniti |
6 | Validate data from pre-load and error reports | Business/Data owner |
7 | Generate load files | Syniti |
Transformation Rules
1. Measurement Document - DCT
| Rule # | Source system | Source Table | Source Field | Source Description | Target System | Target Table | Target Field | Target Description | Transformation Logic |
|---|---|---|---|---|---|---|---|---|---|
| 1 | DCT | - | ZPLANT | Plant | S/4 HANA | - | - | Plant | Direct Mapping This is used to identify the Business Owner |
| 2 | DCT | IMRG | ZLEGACYMDOCM | Measurement Document | S/4 HANA | IMRG | MDOCM | Measurement Document | Internal Number |
| 3 | DCT | IMRG | ZLEGACYPOINT | Legacy Measuring Point | S/4 HANA | IMRG | POINT | Measuring Point | Value Mapping: Measuring Point |
| 4 | DCT | IMRG | IDATE | Date of the Measurement | S/4 HANA | IMRG | IDATE | Date of the Measurement | Direct Mapping |
| 5 | DCT | IMRG | ITIME | Time of Measurement | S/4 HANA | IMRG | ITIME | Time of Measurement | Direct Mapping |
| 6 | DCT | IMRG | MDTXT | Measurement Document Text | S/4 HANA | IMRG | MDTXT | Measurement Document Text | Direct Mapping |
| 7 | DCT | IMRG | REDCV | Measurement Reading in Unit of Entry | S/4 HANA | IMRG | REDCV | Measurement Reading in Unit of Entry | Direct Mapping |
| 8 | DCT | IMRG | ZREADG | Total Counter Reading in Unit of Entry | S/4 HANA | IMRG | READG | Measurement Reading/Total Counter Reading in SI Unit | If Meas Point is not Counter (IMPTT-INDCT <> "X" in DCT): Default Blank (even if value is provided in DCT) If Measuring Point is Counter: If blank, default to the value of REDCV. The below transformation is only required if the load tool does not allow the reading in Unit of Entry: If value is provided, perform the transformation below: Floating point conversion to apply for loading, including conversion to/from SI unit. Consider the unit from the Measuring Point characteristics and compare against table T006 for conversion. Explanation for conversion from Unit of Entry to SI Unit: a) Based on the UOM of the Meas Point (ATNAM from DCT) and derive the UOM from Characteristics DCT (CABN-MSEHI), retrieve record from T006-MSEHI b) With the value: > Multiply by ZAEHL, and > Divide by NENNR If Counter Reading and Total Counter Reading are not the same (REDCV<>ZREADG): This is Counter Replacement Scenario. This loading step can be achieved by setting the total counter reading externally upon counter replacement. |
| 9 | DCT | IMRG | VLCOD | Valuation Code | S/4 HANA | IMRG | VLCOD | Valuation Code | If Measuring Point - Code Group field is blank (IMPTT-CODGR in DCT), default Blank (even if value is provided in DCT) Else: Direct Mapping |
| 10 | - | - | - | - | S/4 HANA | IMRG | READR | Person who Took the Measurement Reading | Derive the value as per Value Mapping: OTH_Migration_Date Relevant Values A2D (using Object ID "9002" and Field Name = "IMRG-READR". |
| 11 |
| - | ZCHUNK | Export File Chunk | If Measuring Point is linked to an active Maintenance Plan, then default to "C" If Measuring Point is linked to APM, then default to "A" (Refer to relevancy criteria for logic) |
List of Custom Target Reports for this object is maintained here: Conversion Specification - Custom Reports Register.
Transformation Mapping
| Mapping Table Name | Mapping Table Description |
|---|---|
</Start CR0282> | |
|
|
| |
| </End CR0282> | |
| Measuring Point | Mapping of legacy Measuring Point to new Measuring Point |
List of Transformation Mappings with additional details is maintained here: Transformation Mappings
Transformation Dependencies
List the steps that need to occur before transformation can commence| Item # | Step Description | Team Responsible |
|---|---|---|
1 | Ensure DCT tables completeness | SyWay Data Team |
2 | Ensure all Transformation mappings are up to date. | SyWay Data Team |
Pre-Load Validation
Project Team
Completeness
| Task | Action |
|---|---|
Verify Record Count | Data team to verify that the total number of relevant records from the source systems is equal to the total number of records in the Preload and Load Sheets. |
Accuracy
| Task | Action |
|---|---|
Conversion Accuracy | Data team to verify that all fields below meet the checks: 1. Mandatory Fields 2. Field and Value Mapping Correctness 3. Null Checks 4. Text Length Checks |
Review error reports | Review and correct the errors. Achieve a zero-error record count as much as possible. Raise defects for data remediated and requiring a correction in the source data. |
Business
Completeness
| Task | Action |
|---|---|
Verify Record Count | Business team to verify that the total number of relevant records from the source systems is equal to the total number of records in the Preload and Load Sheets. |
Accuracy
| Task | Action |
|---|---|
Conversion Accuracy | Business to verify that all the data in the load table/file is accurate as per endorsed transformation/mapping rules (and signed-off data) |
Load
The load process includes:
- Execute the automated data load into target system using load tool or produce the load file if the load must be done manually
- Once the data is loaded to the target system, it will be extracted and prepared for Post Load Data Validation
Load Run Sheet
| Item # | Step Description | Team Responsible |
|---|---|---|
1 | Ensure Pre-load sign-offs are obtained. | SyWay Data team |
2 | Go to the load tool and select the correct load Program. | SyWay Data team |
3 | Proceed with Data load. | SyWay Data team |
4 | Validate few records loaded by accessing standard transactions | SyWay Data team |
5 | Generate the post load reports in the tool. | SyWay Data team |
6 | Log errors as defects, if any and address resolutions. Close defects. | SyWay Data team |
7 | Resolve defects by reupload and re-generate post load reports if necessary. | SyWay Data team |
8 | Business to validate the post load files as part of post-load validation, raise data defects or provide the post-load sign-off. | Business |
9 | Repeat steps 5 to 7 if necessary. | SyWay Data team |
Load Phase and Dependencies
Cutover: 9002 - Measurement Document
Configuration
| Item # | Configuration Item |
|---|---|
| 1 | T002-Language Keys |
| 2 | T006-Units of Measurement |
Conversion Objects
| Object # | Preceding Object Conversion Approach |
|---|---|
| 1007 | Catalog Code Groups & Codes |
| 1012 | Measuring Point |
Error Handling
| Error Type | Error Description | Action Taken |
|---|---|---|
Configuration | Invalid Language Key | Engage Functional team to expedite and fix the error in the system |
Configuration | Invalid Unit of Measurement | Engage Functional team to expedite and fix the error in the system |
Invalid Data | Invalid Catalog Code Group & Codes | Expedite whether the master data is available in the system |
Invalid Data | Invalid Measuring Point | Expedite whether the master data is available in the system |
Post-Load Validation
Project Team
Completeness
| Task | Action |
|---|---|
Verify Count | Data team to verify the record count created in target S/4 HANA by accessing post load reports in dspMigrate or standard reports from S/4 HANA. |
Verify Logs | Check if there is data that failed to load and perform the necessary actions (e.g. register as post load issue, or attempt to load the record again, etc.). |
Accuracy
| Task | Action |
|---|---|
Conversion Accuracy | Data team to verify that the Measurement Document data in target S/4 HANA were loaded correctly via dspMigrate post load reports or standard reports from S/4 HANA. |
Business
Completeness
| Task | Action |
|---|---|
Verify Count | Download Post Load Reports from dspMigrate and verify that the record count loaded in the target S/4 HANA is the same count as the endorsed load file. |
Accuracy
| Task | Action |
|---|---|
Conversion Accuracy | Verify that the Measurement Document data in target S/4 HANA were loaded correctly via dspMigrate post load reports or standard reports from S/4 HANA. |
Key Assumptions
- Measurement Document is in scope based on data design and any exception requested by business.
- Data cleansing has met the required percentage threshold for the specified mock cycle and all preparation activities have been completed.
- Data entries in DCT are target-ready data unless a specific transformation rule is stated for that field in the transformation rules.
- When the Total Counter Reading is the same as the Counter Reading, the loading method for Normal Counter Reading Entry is adopted (Total Counter Reading can be left blank).
- When the Total Counter Reading is not the same as the Counter Reading, the loading method for Total Counter Reading Set Externally is adopted (both Counter Reading and Total Counter Reading is required).
- For Counter Based Plan, the last reading of the Measuring Document will be the input to the Start Counter of the Maintenance Plan Start object.
- All Measurement Document Text are loaded in English log in, as this does not make any difference when displaying the text in front end.
- The going in position for loading of Measurement Document is to combine Counter related and APM related data during the Cutover phase, judging by the speed of load which will not affect the critical path during the cutover window. If the need arises during the loading phase of the various Mock Cycles, then the loads can be split into Pre-Cutover (APM related) and Cutover (Counter related) by re-using an existing field in the system generated target.
</Start CR0282>
- APM related Measurement Documents will be based on the Measuring Points assigned to a list of Functional Location and Equipment generated after the transformation of the respective object. The list will be based on the original requirement (Mapping of APM related Technical Object Type and Mapping of APM related Plants)
</End CR0282>