Mike Kitchens - principle scientist - ADL
The primary function of an elastomeric seal is to maintain the separation of material phases. In general, seals prevent the exit (leaking) of material from a particular system. In addition to preventing leakage they also prevent the introduction of foreign material contaminants into the same system.
Elastomeric seals can be broadly segmented into two primary categories -static seals and dynamic seals. While the basic purpose of each is the same, the design and function can be quite different. As the name suggests, static seals are not exposed to movement while dynamic seals experience a variety of types of movement.
A wide variety of both static and dynamic elastomeric seals are found in modern machinery in practically all market segments. While often easy to overlook, their criticality should not be underestimated. One seemingly minor leak from a small rubber seal has the potential to soon destroy a complex machine.
Materials for Elastomeric Seals
Elastomeric seals can be made from a wide variety of rubber types. The application requirements should dictate the material selection. Specific technical considerations must be addressed in the material selection such as the type/nature media to be sealed, operating temperatures (low/high), static/dynamic function, and product performance requirements. More broadly the product life cycle, warranty cost, and risk of failure must be considered when selecting the right elastomer for the job.
Solvay’s Tecnoflon FKM and FFKM elastomers are uniquely positioned to offer best in class performance for sealing applications. Among all of the elastomer choices for sealing applications Tecnoflon offers the greatest chemical resistance, highest temperature capability, and best balance of low temperature flexibility to meet the most demanding challenges.
Wear resistance of elastomeric seals
Relatively simple industry standard methods for quantifying and establishing the chemical resistance, high temperature capability, and low temperature flexibility of elastomers in a meaningful and comparative way have been used for many years with a proven track record. However, the question of elastomer wear resistance, in particular for dynamic shaft seals, is a different matter. Few methods exist and those that do are often considered poor predictors of actual performance. For example, taber abrasion data is sometimes suggested as an indicator of dynamic seal wear resistance. However, there is sufficient anecdotal evidence of the unreliable wear predictability of tabor data to call into question its relevance. As a result, seal makers and designers have developed numerous highly specialized and often proprietary individualized methods to predict functional performance (including wear) of unique seals in application. These methods, second only to actual validation in service, require significant investment, are highly specialized, sometimes considered proprietary, and the results are often relevant only to a particular application and therefore may not easily translate.
Factors impacting dynamic shaft seal wear performance.
Wear performance of a shaft seal is a complex matter. There are multiple factors at play that impact the wear behavior. They include but are not limited to:
- Intrinsic base polymer properties
- Viscosity
- Cure type
- % Fluorine
- molecular structure (MWD, branching, linearity, etc)
- end group chemistry
- Formulation of the final compound
- Hardness and mechanical property requirements
- Mineral vs black filled vs blends
- Special “wear enhancing” additives
- Process aids
- Compound mixing methodology
- Dispersion and incorporation of compounding ingredients
- Compound mixing/work history
- Molding and tool design
- Knit (weld) lines placement
- Tool venting and gassing
- Engineered waste (Flash) and gassing
- Seal design features
- Lip geometry (shape)
- Lip flexion (modulus vs elongation)
- Spring tension
- Helical pumping features
- Knife trimmed vs molded contact sealing surface
- Adhesion to inserts
- Set up of the actual seal test
- Shaft rugosity/roughness
- Time and temp protocols
- RPM pattern protocols
- Fluid type and amount
- Fluid change intervals
- Seal installation alignment against shaft and bore
It’s clear that from an elastomeric polymer manufacturer’s perspective there is very little beyond the intrinsic properties of the base polymer itself that can significantly influence the wear behavior of the final product. For this reason, most elastomeric polymer manufacturers tend not to focus intently on measuring wear behavior of sealing materials. However, it’s relatively common for seal makers and compounders to inquire of the elastomeric polymer manufacturer about the wear behavior and properties of various materials.
In order to develop a greater understanding of the role and influence the elastomer manufacturer can have regarding the wear behavior of a final sealing product a less complex test should be used that gives relevant information in a simple to measure method. Solvay’s ADL group has developed a test that might be just what is needed. This test uses a simple 0.214 size molded o-ring that is affixed stationary on one side and a rotating counter surface is moved against the opposite side of the o-ring in a controlled way. The test measures material loss, wear band width/depth, and coefficient of friction. The test is quick and simple to operate and so far shows a good distinction between samples of different formulations. Validation of this test is currently underway and the intent is to compare materials of “known good” wear behavior in real world radial shaft seal applications with experimental materials. Once the method is more fully validated, the intent is to work with customers to compare grades, formulations, etc in order to help them optimize their compounds for wear and friction using our Tecnoflon elastomeric polymers