- Dielectric constant and Dissipation Factor
- Dielectric @ 2.5 GHz
- Volume and Surface Resistivity
- CTI – Comparative Tracking Index
- EMI shielding
Dielectric Constant & Dissipation Factor (Dk/Df)ASTM D150: up to 30MHz, LCR meters with parallel plate electrodes and disk/plaque/film samplesASTM D2520: 20KHz-40GHz, VNAs with rectangular prism resonance cavities and bar samplesASTM D2520: 2.45GHz, VNAs with split post resonance cavities and thin film or plaque samplesIPC-TM-650: 5GHz-35GHz, VNAs with split cylinder resonance cavities and thin film or plaque samples
|
|
|---|
Dielectric Strength (Breakdown Voltage)- ASTM D877/1816 and IEC 156: up to 60KV, Hipotronics OC60DI
- ASTM D149: up to 100KV, Hipotronics D149-DI
- Test fixtures (open air and oil filled)
|   |
Volume & Surface Resistivity- ASTM D257: Keithley 6517B & 8009 fixture
- ANSI 11.11/11.12: ETS meter with 803B probes
- ASTM D991: Keithley 2470 with ETS 831
|  
|
Comparative Tracking Index (CTI)ASTM D3638 and IEC 60112Attrezzature Tecniche Speciali equipment2 machines, 600V and 1000V
| |
|---|
EMF Shielding Effectiveness- ASTM D4935: 20KHz-4.8GHz, VNA with custom resonance cavity fitted to this rang
| |