Purpose

The purpose of this document is to define the conversion approach to create 1041 Inspection Plan Conversion Specification Document in S/4 HANA.

Inspection Plans are a core component of SAP Quality Management (QM) that define how materials are inspected, including inspection characteristics, sampling procedures, and inspection methods. An inspection plan contains detailed steps for quality checks and ensures that inspections are carried out in a standardized, repeatable, and compliant manner for specific materials, plants, and usage scenarios.

In SAP S/4HANA, the structure and usage of inspection plans remain largely consistent with SAP ECC, typically organized by key combinations such as material/plant, material group/plant, or multiple materials assigned to the same inspection plan via task lists. Inspection plans may also be linked to specific usage types (e.g., goods receipt, in-process inspection, final inspection) and can be maintained with reference to alternative groupings for flexibility.

In SAP ECC, aside from the standard structures, there may be inspection plans with additional variants such as multiple alternative plans for the same material/plant combination, inspection plans assigned to multiple task list groups, or plans that use reference materials. In some legacy systems, plans may also include non-standard fields or custom enhancements (pending MDS review) that will require evaluation before conversion.

This conversion aims to migrate active and relevant inspection plan master data, including associated operations, inspection characteristics, sampling procedures, and inspection methods, from existing ECC systems into S/4HANA. The migration will apply required transformation logic using Syniti as the data migration and transformation platform. The converted records will be loaded into the target S/4HANA system using standard SAP mechanisms such as BAPIs (e.g., BAPI_INSPECTIONPLAN_CREATE), IDOCs, or direct table loads where applicable, ensuring data consistency and compliance with S/4HANA requirements


Conversion Scope

The scope of this document covers the approach for converting active Inspection Plan from Legacy Source Systems into S/4 HANA system following the TBD Inspection Plan Master Data Design Standard.

From the current system landscape, Inspection Plan data exists separately in the legacy systems (PF2 and WP2), with potential discrepancies in both systems. Harmonization and validation are required to ensure accurate and consolidated data in S/4HANA. While PF2 and WP2 serve as source systems, extensive mapping and transformation logic will be necessary to produce properly formatted load templates in line with the target design.

The data from legacy system includes:

  1. Active Inspection Plans (PLKO) that are in “Released” status (STATU = 4), PLNTY = 'Q' and used in production, quality, or procurement processes within the last three (4) years.
  2. Inspection Plans without deletion flag (PLKO-LOEKZ not set).
  3. Plant-specific Inspection Plans that will be migrated according to the To-Be Plant Mapping (considering new plant definitions).
  4. Inspection Plans assigned to valid materials via MAPL, where the material exists in the Material Master (MARA/MARC) and is in scope for migration.
  5. Inspection Plans with valid Group and Group Counter (PLKO-PLNNR, PLKO-PLNAL)
  6. Inspection Plans containing valid operations (PLPO) that reference existing and active work centers (CRHD).
  7. Inspection Plan characteristics (PLMK) that:
    • Reference valid Master Inspection Characteristics (QPMK)
    • Reference valid Sampling Procedures (QDSV)
    • Reference valid Inspection Methods (QMTB)
  8. Inspection Plans with valid validity dates (PLKO-DATUV)

The data from legacy system excludes:

  1. Inactive Inspection Plans that have not been used in inspection lots for more than three (4) years
  2. Inspection Plans marked for deletion (PLKO-LOEKZ = X)
  3. Inspection Plans belonging to deleted or out-of-scope plants (as per To-Be Plant Mapping)
  4. Inspection Plans with invalid or inconsistent references, such as:
    • Characteristics linked to deleted/inactive MICs
    • Sampling Procedures or Inspection Methods that do not exist in S/4HANA
    • Work Centers flagged for deletion or not migrated
  5. Inspection Plans with invalid validity dates (Valid-From date into the future PLKO-DATUV).

Relevancy rule

Use the below rules for relevancy criteria.

1. Inspection Plans assigned to valid materials via MAPL, where the material exists in the Material Master (MARA/MARC) and is in scope for migration.

2. Active Inspection Plans (PLKO) that are in “Released” status (STATU = 4), PLNTY = 'Q' and used in production, quality, or procurement processes within the last three (4) years.

QALS-ENSTEHDAT >= (CURRENT DATE -  4 Years) AND QALS-PLNNR = PLKO-PLNNR AND QALS-PLNAL = PLKO-PLNAL AND PLKO-PLNTY = 'Q' AND

PLKO-STATU = '4' & PLKO-LOEKZ = Blank & PLPO-LOEKZ = Blank and PLKO-DATUV > CURRENT DATE

3. Inspection Plans containing valid operations (PLPO) that reference existing and active work centers (CRHD).

4. Inspection Plan characteristics (PLMK) that

  • Reference valid Master Inspection Characteristics (QPMK)
  • Reference valid Sampling Procedures (QDSV)
  • Reference valid Inspection Methods (QMTB)


Plant Merging

Plants will be harmonized based on the To-Be Plant Mapping. As some legacy plants will be merged into one target plant, Inspection Plans will be reassigned accordingly. Plant transformation will be managed through a mapping table maintained in Syniti to ensure consistent alignment with the To-Be Plant structure.



List of source systems and approximate number of records


SourceScope

Source Approx No. of Records

Target SystemTarget Approx

No. of Records

PF2/WP2

Inspection Plan will be extracted from PF2 and WP2  

PF2 = 8129 records

WP2 = 37451 records

S/4 HANA

13209 records

Additional Information

Multi-language Requirement

Inspection Plan description will be maintained in English by default.

Since multi-language support is available for Inspection Plan, users logging in with a different language will see the description displayed in their logon language, provided that the corresponding language key has been maintained in the on Inspection Plan.

Document Management

None identified. The conversion scope is limited to the migration of Inspection Plan object. No document attachments, images, or supporting files are included.

Legal Requirement

Not applicable

Special Requirements

Not applicable



Target Design

Inspection Plan strictly adheres to the Master Data Standard. The complete information of the tables and key fields that hold the Inspection Plan information follows the Master Data Standard document.

The technical design of the target for this conversion approach

TableFieldData ElementField DescriptionData TypeLengthRequirement
PLKOPLNTYPLNTYKey which classifies task lists according to their functionality.
In the QM context this value is defaulted to "Q"
CHAR1R
PLKOPLNNRPLNNRKey that uniquely identifies an Inspection Plan Group.CHAR8S
PLKOPLNALPLNALKey that identifies an Inspection Plan within a Task List Group.CHAR2R
PLKOZAEHLCIM_COUNTInternal Counter to link the tables to ensure the data consistencyNUMC8S
PLKODATUVDATUVDate from which the an Inspection Plan object is valid.DATS8R
PLKOVALID_TODATUBEnd of the validity period of the Inspection Plan object.DATS8R
PLKOAENNRAENNRKey for the change master record or engineering change order that the chosen change status of the Inspection Plan object was created with.
Can be used for Customer Spec Updates
CHAR12NU
PLKOVERWEPLN_VERWEKey indicating what the Inspection Plan is used for, such as Inspection for GR, Recurring Inspection, Goods Issue.CHAR3R
PLKOWERKSWERKS_DPlant of the material to be inspected.CHAR4R
PLKOSTATUPLNSTStatus key to indicate the processing status of an Inspection Plan. For example, indicate whether the recipe is still in the creation phase or has already been released.CHAR3R
PLKOPLNMEPLNMEUnit of measure of the charge quantityUNIT3R
PLKOLOSVNLOSGRVONLower limit of the charge quantity range for which the recipe is valid.QUAN13NU
PLKOLOSBSLOSGRBISUpper limit of the charge quantity range for which the recipe is valid.QUAN13NU
PLKOVAGRPVAGRPKey of the planner group responsible for maintaining the Inspection Plan.CHAR3C
PLKOKTEXTPLANTEXTDescribes the Inspection PlanCHAR40R
PLKOTXTSPSPRASLanguage keyLANG1S
PLKOLOEKZLKENZIndicator set if the Inspection Plan to be completely deleted at the next reorganization run, with all its change states.CHAR1S
PLKOQKZRASTERQKZRASTERIdentifier for Inspection Point Field Combination
Inspection points are used as reference objects for recording inspection results below operation level.
If a value is entered for the inspection point, this value is copied to the inspection lots.
CHAR1C
PLKOQPRZIEHVERQPRZIEHVERA master data object in QM sample management that contains instructions for a sample drawing.CHAR8C
PLKOQDYNREGELQDYNREGELContains the definition of inspection stages and the conditions that lead to changes in inspection stages.CHAR3C
PLKOQDYNHEADQDYNHEADIdentifies the level at which the decision for inspection stages is made and the quality level maintained.CHAR1NU
MAPLMATNRMATNRMaterial Number for witch the recipe is createdCHAR40R
MAPLWERKSWERKS_DPlantCHAR4R
MAPLPLNTYPLNTYKey which classifies task lists according to their functionality.
In the QM context this value is defaulted to "Q"
CHAR1R
MAPLPLNNRPLNNRKey that uniquely identifies an Inspection Plan Group.CHAR8S
MAPLPLNALPLNALThis key and the task list group uniquely identify a task list.CHAR2S
MAPLZKRIZDZKRIZInternal Counter to link the tables to ensure the data consistencyNUMC7S
MAPLZAEHLCIM_COUNTInternal Counter to link the tables to ensure the data consistencyNUMC8S
MAPLLIFNRELIFNSupplierCHAR10C
MAPLKUNRCPKUNRCustomerCHAR10C
PLPOPLNTYPLNTYKey which classifies task lists according to their functionality.
In the QM context this value is defaulted to "Q"
CHAR1R
PLPOPLNNRPLNNRKey that uniquely identifies an Inspection Plan Group.CHAR8S
PLPOPLNALPLNALKey that identifies an Inspection Plan within a Task List Group.CHAR2R
PLPOZAEHLCIM_COUNTInternal Counter to link the tables to ensure the data consistencyNUMC8S
PLPOVORNRVORNRDetermines in which order the operations of a sequence are carried out.CHAR4R
PLPOARBIDOBJEKTIDWorkcenter used to perform the QM activityNUMC8R
PLPOSTEUSSTEUSDetermines which business transactions should be executed for the object that belongs to the task list or order (for example scheduling or costing).CHAR4R
PLPOLTXA1LTXA1Operation Short TextCHAR40C
PLPOBMSCHBMSCHQuantity of the material to be inspected to which the standard values of the operation refer.QUAN13R
PLPOMEINHVORMEUnit of measure used in the operation for the material to be inspected.UNIT3R
PLPOWERKSWERKS_DPlantCHAR4R
PLPOLAR01LSTARActivity TypeCHAR6NU
PLPOVGE01VGWRTEHUnit of Measurement of Standard ValueUNIT3NU
PLPOVGW01VGWRT
QUAN9NU
PLMKPLNTYPLNTYKey which classifies task lists according to their functionality.
In the QM context this value is defaulted to "Q"
CHAR1R
PLMKPLNNRPLNNRKey that uniquely identifies an Inspection Plan Group.CHAR8S
PLMKPLNKNPLNKNThe Node field represents the unique identifier of a task list node, which links an operation in a task list to specific inspection characteristicsNUMC8S
PLMKMERKNRQMERKNRPThe number that explicitly identifies an inspection characteristic within an operation in an inspection plan.NUMC4R
PLMKVERWMERKMQMERKNRMaster Inspection CharacteristicsCHAR8R
PLMKKZEINSTELLQKZEINSTMKCharacteristic Type: Quantitative or QualitativeCHAR1S
PLMKZAEHLCIM_COUNTInternal Counter to link the tables to ensure the data consistencyNUMC8S
PLMKQPMK_ZAEHLQZAEHLERPlantCHAR4R
PLMKMKVERSIONQVERSNRMKVersion Number of Master Inspection CharacteristicCHAR6S
PLMKKURZTEXTQTXT_CHAText of up to 40 characters that describes the object in more detail. This description is also known as short text.CHAR40C
PLMKPMETHODEQPMETHODEAn inspection method describes how to inspect an inspection characteristic. You can assign an inspection method to a master inspection characteristic or directly to an inspection characteristic in an inspection plan.CHAR8C
PLMKQMTB_WERKSQ_METH_PLANTPlant for Inspection MethodCHAR4S
PLMKPMTVERSIONQVERSNRPMVersion Number of Inspection MethodCHAR6S
PLMKSTICHPRVERQSTICHVERFProcedure by which the sample size for an inspection is determined.
In the sampling procedure, the valuation mode is also defined for the inspection result.
CHAR8R
PLMKMASSEINHSWQMASSEHMeasurement Unit in Which Quantitative Data Is Maintained
Specifies the unit of measurement for the proposed values of a quantitative inspection characteristic (for example, target value, specification limits). You have 6 digits to specify the unit of measurement.
UNIT3S
PLMKSOLLWERTQSOLLWERTETarget Value for a Quantitative Characteristic
Value of a quantitative characteristic, from which the actual value of the inspection characteristic should deviate as little as possible.
FLTP16R
PLMKTOLERANZUNQTOLUNLower Specification Limit
Lower limiting value for the actual value of an inspection characteristic.
FLTP16R
PLMKTOLERANZOBQTOLOBUpper Specification Limit
Upper limit value for the actual value of an inspection characteristic.
FLTP16R
PLMKAUSWMENGE1QCGRAUSWIf the characteristic is qualitative with a characteristic attribute you can enter a selected set in this field.CHAR8R
PLMKAUSWMGWRK1QWERKAUSWPlant of assigned selected setCHAR4S
PLMKDUMMY10QTXT10Text Line for Additional Information_1CHAR10NU
PLMKDUMMY20QTXT20Text Line for Additional Information_2CHAR20NU
PLMKDUMMY40QTXT40Text Line for Additional Information_3CHAR40NU
PLMKGRENZEOB1QGRENZOB1Upper limit value of a user-specified limit, for example, a warning limit.
The system does not use the contents of this field. This field provides a place to store a user-specified limit value that is relevant
FLTP16NU
PLMKGRENZOB1NIQNINITIALValue Not Initial If SetCHAR1NU
PLMKGRENZEUN1QGRENZUN1Lower limiting value of a user-specified limit, for example, a warning limit
The system does not use the contents of this field. This field provides a place to store a user-specified limit value that is relevant for a quantitative characteristic.
FLTP16NU
PLMKGRENZUN1NIQNINITIALValue Not Initial If SetCHAR1NU
PLMKGRENZEOB2QGRENZOB2Upper limit value of a user-specified limit, for example, a warning limit.
The system does not use the contents of this field. This field provides a place to store a user-specified limit value that is relevant
FLTP16NU
PLMKGRENZOB2NIQNINITIALValue Not Initial If SetCHAR1NU
PLMKGRENZEUN2QGRENZUN2Lower limiting value of a user-specified limit, for example, a warning limit
The system does not use the contents of this field. This field provides a place to store a user-specified limit value that is relevant for a quantitative characteristic.
FLTP16NU
PLMKGRENZUN2NIQNINITIALValue Not Initial If SetCHAR1NU
PLMKPLAUSIOBENQPLAUSIOBMaximum plausible value of a plausibility limit.It protects against the recording and processing of invalid or improbable valuesFLTP16C
PLMKPLAUSIOBNIQNINITIALValue Not Initial If SetCHAR1S
PLMKPLAUSIUNTEQPLAUSIUNMinimum plausible value of a plausibility limit.This field is used only for results recording of quantitative characteristics. It protects against the recording and processing of invalid or improbable values.FLTP16C
PLMKPLAUSIUNNIQNINITIALValue Not Initial If SetCHAR1S
PLMKTOLERWEIOBQTOLWOBAmount by which the specification limit is temporarily increased or decreased.FLTP16NU
PLMKTOLWOBNIQNINITIALValue Not Initial If SetCHAR1S
PLMKTOLERWEIUNQTOLWUNAmount by which the specification limit is temporarily increased or decreased.FLTP16NU
PLMKTOLWUNNIQNINITIALValue Not Initial If SetCHAR1S
PLMKTOLERWABQTOLWABDate from Which the Tolerance Change Is ValidDATS8C
PLMKTOLERWBISQTOLWBISDate Until Which the Tolerance Change Is ValidDATS8C


Data Cleansing

IDCriticalityError Message/Report DescriptionRuleOutputSource System
1006-001C1Invalid or inactive Work Center linked to OperationOperation (PLPO) assigned to a Work Center (CRHD) that does not exist or is flagged for deletion.Work CenterPF2/WP2
1041-001C1Inspection Plan not releasedHeader (PLKO-STATU) not set to “Released” (status = 4). Only released plans are migrated.Inspection Plan HeaderPF2/WP2
1041-002C1Invalid Usage assignmentInspection plan header (PLKO-VERWE) has an invalid or non-configured Task List Usage.UsagePF2/WP2
1041-003C1Missing or invalid Group CounterInspection plan (PLKO-PLNAL) is blank, duplicated, or inconsistent with group.Plan CounterPF2/WP2
1041-004C1Invalid Validity DateValid-From date (PLKO-DATUV) is in the future or overlaps inconsistently with other plans for same material/usage.Inspection Plan HeaderPF2/WP2
1041-005C1Obsolete Inspection PlanHeader marked with deletion flag (PLKO-LOEKZ = X). Exclude from migration.Inspection Plan HeaderPF2/WP2
1043-001C1Missing or Invalid Inspection MethodPlan characteristic (PLMK-PRFGEB) references an Inspection Method (QMTB) that does not exist, is obsolete, or not valid for plant.Inspection MethodPF2/WP2
1057-001C1Invalid Inspection CharacteristicPlan characteristic (PLMK) references a Master Inspection Characteristic (QPMK) that does not exist, is inactive, or marked for deletion.Master Insp. CharacteristicPF2/WP2
1057-002C1Inconsistent Quantitative/Qualitative SettingsPlan characteristic (PLMK-QUALI) is inconsistent with assigned MIC type (quantitative/qualitative).CharacteristicPF2/WP2
1057-003C1Duplicate Inspection CharacteristicsInspection plan contains duplicate operation/characteristic entries (same VORNR + MERKNR).Inspection Plan Operations/CharacteristicsPF2/WP2
1064-001C1Missing Sampling ProcedurePlan characteristic (PLMK-STICHPRVER) references a Sampling Procedure (QDSV) that does not exist or is obsolete.Sampling ProcedurePF2/WP2
2009-001C1Invalid or inactive Material Assignment in Inspection PlanInspection plan (MAPL) is assigned to a material/plant that does not exist or is inactive in Material Master (MARA/MARC).Material MasterPF2/WP2



Conversion Process

The high-level process is represented by the diagram below:

The ETL (Extract, Transform, Load) process is a structured approach to data migration and management, ensuring high-quality data is seamlessly transferred across systems. Here’s a breakdown of its key components:

1. Extraction
The process begins with extracting metadata and raw data from source systems, such as Syensqo ECC system (i.e. WP2/PF2) periodically. The extracted data is then staged for transformation.


2. Transformation
Once extracted, the data undergoes cleansing, consolidation, and governance. This step ensures data integrity, consistency, and compliance with business rules. The transformation process includes:
- Data validation to remove inconsistencies.
- Standardization to align formats across datasets.
- Business rule application to refine data for operational use.


3. Loading
The transformed data is then loaded into the target S/4HANA system. 

Legacy.png

Data Privacy and Sensitivity

Not applicable


Extraction

Extract data from a source into Syniti Migrate. There are 2 possibilities:

  1. The data exists. Syniti Migrate connects to the source and loads the data into Syniti Migrate. There are 3 methods:
    1. Perform full data extraction from relevant tables in the source system(s).
    2. Perform extraction through the application layer.
    3. Only if Syniti Migrate; cannot connect to the source, data is loaded to the repository from the provided source system extract/report.
  2. The data does not exist (or cannot be converted from its current state).  The data is manually collected by the business directly in Syniti Migrate. This is to be conducted using DCT (Data Collection Template) in Syniti Migrate.

The agreed relevancy criteria is applied to the extracted records to identify the records that are applicable for the Target Loads

Extraction Run Sheet

Req #Requirement DescriptionTeam Responsible
Extraction Scope Definition- Identify the source systems and databases involved.
- Define the data objects (tables, fields, records) to be extracted.
- Establish business rules for data selection.

Syniti /P2F Data team

Extraction Methodology- Specify the extraction approach (full, incremental, or delta extraction).
- Determine the tools and technologies used.
- Define data filtering criteria to exclude irrelevant records.
Syniti 
Extraction Execution Plan- Establish execution timelines and batch processing schedules.
- Assign responsibilities for extraction monitoring.
- Document dependencies on other migration tasks.
Syniti
Data Quality and Validation- Define error handling mechanisms for extraction failures.Syniti


Selection Screen

Selection Ref ScreenParameter NameSelection TypeRequirementValue to be entered/set
Not applicable



















Data Collection Template (DCT)

The Data Collection Template (DCT) will not be applicable in this case. If there is a need to create a new Master Data (MD) for Inspection Plan object, the business must perform this activity in the source system. The newly created object will then be captured and migrated as part of the standard migration process.


Extraction Dependencies

Item #Step DescriptionTeam Responsible
1

Source System Availability

  • Ensure that the source database or application is accessible.
  • Confirm that necessary credentials and permissions are granted

Syensqo IT

2

Data Structure

  • Identify relationships between tables, views, and stored procedures.

Syniti

3

Referential Integrity

  • Ensure dependent records are extracted together.

Syniti

4

Extraction Methodology

  • Define whether extraction is full, incremental, or delta-based.
  • Establish batch processing schedules for large datasets.

Syniti

5

Performance and Scalability Considerations

  • Optimize extraction queries to prevent system overload.
  • Ensure network bandwidth supports data transfer volumes.

Syniti

6

Security and Compliance

  • Adhere to regulatory standards for sensitive information if applicable

Syniti

7

Data cleansing of legacy Material Master - QM View with assigned inspection type data must be completed.

If standardization within the DCT begins using relevant data from PF2 and WP2 before the cleansing is finalized, it is understood that the business will take due diligence to ensure any subsequent delta cleansing is verified and aligned within the DCT.

Business


Transformation

The Target fields are mapped to the applicable Legacy field that will be its source, this is a 3-way activity involving the Business, Functional team and Data team. This identifies the transformation activity required to allow to make the data Target ready:

  1. Perform value mapping and data transformation rules.
    1. Legacy values are mapped to the to-be values (this could include a default value)
    2. Values are transformed according to the rules defined in
  2. Prepare target-ready data in the structure and format that is required for loading via prescribed Load Tool. This step also produces the load data ready for business to perform Pre-load Data Validation

Transformation Run Sheet

Item #Step DescriptionTeam Responsible

1

Transformation Scope Definition

- Identify the source and target data structures.

- Define business rules for data standardization.

- Establish data cleansing requirements to remove inconsistencies.

Data Team

2

Data Mapping and Standardization

- Align source fields with target fields.

- Ensure unit consistency (e.g., currency, measurement units)

Data Team

3

Business Rule Application

- Implement data enrichment/collection if applicable

- Apply conditional transformations based on predefined logic/business rules

Data Team

4

Transformation Execution Plan

- Define batch processing schedules.

- Assign responsibilities for monitoring execution.

- Establish error-handling mechanisms

Syniti


Transformation Rules

Rule #Source SystemSource TableSource FieldSource DescriptionTarget SystemTarget TableTarget FieldTarget DescriptionTransformation Logic
1PF2/WP2PLKOPLNTYTask List Type(Q = Inspection Plant)S/4 HANAPLKOPLNTYTask List Type(Q = Inspection Plant)R.Default to "Q"
2PF2/WP2PLKOPLNNRKey for Task List GroupS/4 HANAPLKOPLNNRKey for Task List GroupS.Internal
3PF2/WP2PLKOPLNALGroup Counter(Alternative)S/4 HANAPLKOPLNALGroup Counter(Alternative)R.Internal
4PF2/WP2PLKOZAEHLCounterS/4 HANAPLKOZAEHLCounterS.Internal
5PF2/WP2PLKODATUV
Valid-From Date
S/4 HANAPLKODATUV
Valid-From Date
R.Internal
6PF2/WP2PLKOVALID_TOValid-to dateS/4 HANAPLKOVALID_TOValid-to dateR. Default to '31.12.9999'
7PF2/WP2PLKOAENNRChange NumberS/4 HANAPLKOAENNRChange NumberNot used
8PF2/WP2PLKOVERWETask List UsageS/4 HANAPLKOVERWETask List UsageR: In case of Inspection Type 01,05 and 08 use 5 Usage. In case of Inspection Type 89 use task list 3, in case of Inspection Type 02, 06, 10, 11, 12 use the task list 6, in case of Inspection Type 09 use the 09 Task list
Rule:
Step1: Join MAPL, QMAT/MARC on MATNR,WERKS, QMAT-ART(Inspection type)
Setp2:
If Inspection Type in 01,05 and 08 then Map usage(VERWE) = 5
       If Inspection Type is 89 then Map usage(VERWE) = 3
       in case of Inspection Type 02, 06, 10, 11, 12 then Map usage(VERWE) = 6
       in case of Inspection Type 09 then Map usage(VERWE) = 09
9PF2/WP2PLKOWERKSPlantS/4 HANAPLKOWERKSPlantR. Xref: Use xref for Plant (per mapping file)
10PF2/WP2PLKOSTATUStatusS/4 HANAPLKOSTATUStatusR. Only migrate Released (4) plans. Others excluded (cleansing).
Default to 4
11PF2/WP2PLKOPLNMETask List Unit of MeasureS/4 HANAPLKOPLNMETask List Unit of MeasureR.Copy from source system
12PF2/WP2PLKOLOSVN
Minimum Lot Size
S/4 HANAPLKOLOSVN
Minimum Lot Size
Not used
13PF2/WP2PLKOLOSBSMaximum Lot SizeS/4 HANAPLKOLOSBSMaximum Lot SizeNot used
14PF2/WP2PLKOVAGRPResponsible Planner Group or DepartmentS/4 HANAPLKOVAGRPResponsible Planner Group or DepartmentC. Xref: Use xref for VAGRP (per mapping file)
15PF2/WP2PLKOKTEXTrecipe DescriptionS/4 HANAPLKOKTEXTrecipe DescriptionR. Copy from Source system
16PF2/WP2PLKOTXTSPLanguage KeyS/4 HANAPLKOTXTSPLanguage KeyS.Internal
17PF2/WP2PLKOLOEKZDeletion IndicatorS/4 HANAPLKOLOEKZDeletion IndicatorS.Internal
18PF2/WP2PLKOQKZRASTERInspection PointS/4 HANAPLKOQKZRASTERInspection PointC. Copy from source system
19PF2/WP2PLKOQPRZIEHVERSample-Drawing ProcedureS/4 HANAPLKOQPRZIEHVERSample-Drawing ProcedureC. Xref: Use xref for Sample drawing procedure (per mapping file)
20PF2/WP2PLKOQDYNREGELDynamic Modification ruleS/4 HANAPLKOQDYNREGELDynamic Modification ruleC. Xref: Use xref for Dynamic modification rule (per mapping file)
21PF2/WP2PLKOQDYNHEADLevel at Which Dynamic Modification Parameters Are DefinedS/4 HANAPLKOQDYNHEADLevel at Which Dynamic Modification Parameters Are DefinedNot used
22PF2/WP2MAPLMATNRMaterial NumberS/4 HANAMAPLMATNRMaterial NumberR. Xref: Use xref for Material (per mapping file)
23PF2/WP2MAPLWERKSPlantS/4 HANAMAPLWERKSPlantR. Xref: Use xref for Plant (per mapping file)
24PF2/WP2MAPLPLNTYTask List TypeS/4 HANAMAPLPLNTYTask List TypeR. Default to "Q"
25PF2/WP2MAPLPLNNRKey for Task List GroupS/4 HANAMAPLPLNNRKey for Task List GroupS.Internal
26PF2/WP2MAPLPLNALGroup CounterS/4 HANAMAPLPLNALGroup CounterS.Internal
27PF2/WP2MAPLZKRIZCounter for Additional CriteriaS/4 HANAMAPLZKRIZCounter for Additional CriteriaS.Internal
28PF2/WP2MAPLZAEHLCounterS/4 HANAMAPLZAEHLCounterS.Internal
29PF2/WP2MAPLLIFNRSupplierS/4 HANAMAPLLIFNRSupplierC.Xref: Use xref for Supplier (per mapping file)
30PF2/WP2MAPLKUNRCustomerS/4 HANAMAPLKUNRCustomerC.Xref: Use xref for Customer (per mapping file)
31PF2/WP2PLPOVORNROperationS/4 HANAPLPOVORNROperationR. Copy from Source system
Re-sequence 0010… if duplicates
32PF2/WP2PLPOPLNTYTask List Type(Q = Inspection Plant)S/4 HANAPLPOPLNTYTask List Type(Q = Inspection Plant)R. Default to "Q"
33PF2/WP2PLPOPLNNRKey for Task List GroupS/4 HANAPLPOPLNNRKey for Task List GroupS.Internal
34PF2/WP2PLPOPLNALGroup Counter(Alternative)S/4 HANAPLPOPLNALGroup Counter(Alternative)R.Internal
35PF2/WP2PLPOZAEHLCounterS/4 HANAPLPOZAEHLCounterS.Internal
36PF2/WP2PLPOARBIDWorkcenterS/4 HANAPLPOARBIDWorkcenter

R :  PLPO-ARBID = CRHD-OBJID that represent the Workcenter CRHD-ARBPL

Xref: Use xref for Workcenter(Per mapping file)

37PF2/WP2PLPOSTEUSControl KeyS/4 HANAPLPOSTEUSControl KeyR: Default to "QM01"
38PF2/WP2PLPOLTXA1Operation Short TextS/4 HANAPLPOLTXA1Operation Short TextC: Copy from Source system
39PF2/WP2PLPOBMSCHBase quantityS/4 HANAPLPOBMSCHBase quantityR. Copy from Source system
40PF2/WP2PLPOMEINHUnit of measure for activityS/4 HANAPLPOMEINHUnit of measure for activityR. Copy from Source system
41PF2/WP2PLPOWERKSPlantS/4 HANAPLPOWERKSPlantR. Xref: Use xref for Plant (per mapping file)
42PF2/WP2PLPOLAR01Activity TypeS/4 HANAPLPOLAR01Activity TypeNot used
43PF2/WP2PLPOVGE01Unit of Measurement of Standard ValueS/4 HANAPLPOVGE01Unit of Measurement of Standard ValueNot used
44PF2/WP2PLPOVGW01Standard ValueS/4 HANAPLPOVGW01Standard ValueNot used
45PF2/WP2PLMKPLNTYTask List Type(Q = Inspection Plant)S/4 HANAPLMKPLNTYTask List Type(Q = Inspection Plant)R. Default to "Q"
46PF2/WP2PLMKPLNNRKey for Task List GroupS/4 HANAPLMKPLNNRKey for Task List GroupS.Internal
47PF2/WP2PLMKPLNKNNodeS/4 HANAPLMKPLNKNNodeS.Internal
48PF2/WP2PLMKMERKNRInspection Characteristic NumberS/4 HANAPLMKMERKNRInspection Characteristic NumberR. Copy; if missing, derive sequentially per operation (0001…n)
49PF2/WP2PLMKVERWMERKM
Master Inspection Characteristic
S/4 HANAPLMKVERWMERKM
Master Inspection Characteristic
R. Xref: Use xref for MIC (per mapping file)
50PF2/WP2PLMKKZEINSTELL

Characteristic Type

S/4 HANAPLMKKZEINSTELLCharacteristic TypeS.Internal
51PF2/WP2PLMKZAEHLCounterS/4 HANAPLMKZAEHLCounterS.Internal
52PF2/WP2PLMKQPMK_ZAEHLPlantS/4 HANAPLMKQPMK_ZAEHLPlantR. Xref: Use xref for Plant (per mapping file)
53PF2/WP2PLMKMKVERSIONVersionS/4 HANAPLMKMKVERSIONVersionS.Internal
54PF2/WP2PLMKKURZTEXTShort Text for Inspection CharacteristicS/4 HANAPLMKKURZTEXTShort Text for Inspection CharacteristicC. Copy from source system
55PF2/WP2PLMKPMETHODEInspection MethodS/4 HANAPLMKPMETHODEInspection MethodC.Xref: Use xref for Inspection Method (per mapping file)
56PF2/WP2PLMKQMTB_WERKSPlant for Inspection MethodS/4 HANAPLMKQMTB_WERKSPlant for Inspection MethodS.Internal
57PF2/WP2PLMKPMTVERSIONVersion Number of Inspection MethodS/4 HANAPLMKPMTVERSIONVersion Number of Inspection MethodS.Internal
58PF2/WP2PLMKSTICHPRVERSampling Procedure in Inspection CharacteristicS/4 HANAPLMKSTICHPRVERSampling Procedure in Inspection CharacteristicR. Xref: Use xref for Sample procedure (per mapping file)
System expects a value if we have MIC
59PF2/WP2PLMKMASSEINHSWMIC UoMS/4 HANAPLMKMASSEINHSWMIC UoMS.Internal
60PF2/WP2PLMKSOLLWERTTarget ValueS/4 HANAPLMKSOLLWERTTarget ValueR.Copy from Source system
61PF2/WP2PLMKTOLERANZUNLower Specification LimitS/4 HANAPLMKTOLERANZUNLower Specification LimitR.Copy from Source system
62PF2/WP2PLMKTOLERANZOBUpper Specification LimitS/4 HANAPLMKTOLERANZOBUpper Specification LimitR.Copy from Source system
63PF2/WP2PLMKAUSWMENGE1Assigned Code Group or Selected SetS/4 HANAPLMKAUSWMENGE1Assigned Code Group or Selected SetR.Xref: Use xref for Code group or Selected set
64PF2/WP2PLMKAUSWMGWRK1Plant of the Assigned Selected SetS/4 HANAPLMKAUSWMGWRK1Plant of the Assigned Selected SetS.Internal
65PF2/WP2PLMKDUMMY10Text Line for Additional Information_1S/4 HANAPLMKDUMMY10Text Line for Additional Information_1Not used
66PF2/WP2PLMKDUMMY20Text Line for Additional Information_2S/4 HANAPLMKDUMMY20Text Line for Additional Information_2Not used
67PF2/WP2PLMKPLMK-DUMMY40Text Line for Additional Information_3S/4 HANAPLMKPLMK-DUMMY40Text Line for Additional Information_3Not used
68PF2/WP2PLMKGRENZEOB1First Upper Specification LimitS/4 HANAPLMKGRENZEOB1First Upper Specification LimitNot used
69PF2/WP2PLMKGRENZOB1NIValue Not Initial If SetS/4 HANAPLMKGRENZOB1NIValue Not Initial If SetNot used
70PF2/WP2PLMKGRENZEUN1First Lower Specification LimitS/4 HANAPLMKGRENZEUN1First Lower Specification LimitNot used
71PF2/WP2PLMKGRENZUN1NIValue Not Initial If SetS/4 HANAPLMKGRENZUN1NIValue Not Initial If SetNot used
72PF2/WP2PLMKGRENZEOB2Second Upper Specification LimitS/4 HANAPLMKGRENZEOB2Second Upper Specification LimitNot used
73PF2/WP2PLMKGRENZOB2NIValue Not Initial If SetS/4 HANAPLMKGRENZOB2NIValue Not Initial If SetNot used
74PF2/WP2PLMKGRENZEUN2Second Lower Specification LimitS/4 HANAPLMKGRENZEUN2Second Lower Specification LimitNot used
75PF2/WP2PLMKGRENZUN2NIValue Not Initial If SetS/4 HANAPLMKGRENZUN2NIValue Not Initial If SetNot used
76PF2/WP2PLMKPLAUSIOBENUpper Plausibility LimitS/4 HANAPLMKPLAUSIOBENUpper Plausibility LimitC: Copy from Source system
77PF2/WP2PLMKPLAUSIOBNIValue Not Initial If SetS/4 HANAPLMKPLAUSIOBNIValue Not Initial If SetS: Internal
78PF2/WP2PLMKPLAUSIUNTELower Plausibility LimitS/4 HANAPLMKPLAUSIUNTELower Plausibility LimitC: Copy from Source system
79PF2/WP2PLMKPLAUSIUNNIValue Not Initial If SetS/4 HANAPLMKPLAUSIUNNIValue Not Initial If SetS: Internal
80PF2/WP2PLMKTOLERWEIOBChange to Upper Specification LimitS/4 HANAPLMKTOLERWEIOBChange to Upper Specification LimitNot used
81PF2/WP2PLMKTOLWOBNIValue Not Initial If SetS/4 HANAPLMKTOLWOBNIValue Not Initial If SetS: Internal
82PF2/WP2PLMKTOLERWEIUNChange to Lower Specification LimitS/4 HANAPLMKTOLERWEIUNChange to Lower Specification LimitNot used
83PF2/WP2PLMKTOLWUNNIValue Not Initial If SetS/4 HANAPLMKTOLWUNNIValue Not Initial If SetS: Internal
84PF2/WP2PLMKTOLERWABDate from Which the Tolerance Change Is ValidS/4 HANAPLMKTOLERWABDate from Which the Tolerance Change Is ValidC: Rule: If PLMK-TOLERWEIOB or PLMK-TOLERWEIUN is not empty this field need to be populated;
85PF2/WP2PLMKTOLERWBISDate Until Which the Tolerance Change Is ValidS/4 HANAPLMKTOLERWBISDate Until Which the Tolerance Change Is ValidC: Rule: If PLMK-TOLERWEIOB or PLMK-TOLERWEIUN is not empty this field need to be populated;
86PF2/WP2STXHTDOBJECTText Object (e.g., “STKO”)S/4HANASTXHTDOBJECTText Object (e.g., “ROUTING”)Default to"ROUTING"
87PF2/WP2STXHTDNAMEText Name (Combination of BOM Number + Language + Key)S/4HANASTXHTDNAMEText Name
PLKO : MANDT+PLNTY+PLNNR+PLNAL+ZAEHL
PLPO :
MANDT+PLNTY+PLNNR+PLNKN+ZAEHL
The STXH table data will be migrated as-is from the current system to S/4HANA, with no modifications, ensuring consistency and traceability of existing records.
88PF2/WP2STXHTDIDText ID (e.g., “ST”)S/4HANASTXHTDIDText ID: PLKO,PLPOThe STXH table data will be migrated as-is from the current system to S/4HANA, with no modifications, ensuring consistency and traceability of existing records.
89PF2/WP2STXHTDSPRASLanguage KeyS/4HANASTXHTDSPRASLanguage KeyThe STXH table data will be migrated as-is from the current system to S/4HANA, with no modifications, ensuring consistency and traceability of existing records.
90PF2/WP2STXHTDVERSIONVersion Number of TextS/4HANASTXHTDVERSIONVersion Number of TextThe STXH table data will be migrated as-is from the current system to S/4HANA, with no modifications, ensuring consistency and traceability of existing records.
91PF2/WP2STXHTDLOCKLock Indicator for TextS/4HANASTXHTDLOCKLock Indicator for TextThe STXH table data will be migrated as-is from the current system to S/4HANA, with no modifications, ensuring consistency and traceability of existing records.
92PF2/WP2STXLCLUSTDText Line (Compressed)S/4HANASTXLCLUSTDText Line (Compressed)The STXL table data will be migrated as-is from the current system to S/4HANA, with no modifications, ensuring consistency and traceability of existing records.
93PF2/WP2STXLTDOBJECTText Object (Reference from STXH)S/4HANASTXLTDOBJECTText Object (Reference from STXH)Default to"ROUTING"
94PF2/WP2STXLTDNAMEText NameS/4HANASTXLTDNAMEText NameThe STXL table data will be migrated as-is from the current system to S/4HANA, with no modifications, ensuring consistency and traceability of existing records.
95PF2/WP2STXLTDSPOText Line SequenceS/4HANASTXLTDSPOText Line SequenceThe STXL table data will be migrated as-is from the current system to S/4HANA, with no modifications, ensuring consistency and traceability of existing records.


Transformation Mapping

Mapping Table NameMapping Table Description
PlantMapping of legacy Plants to To-Be Plants in S/4HANA (used for PLKO/PLPO/PLMK and MAPL).
Work CenterMapping of legacy Work Centers (CRHD-ARBPL) to new Work Centers in the target plant.
Task List UsageMapping of legacy Task List Usage (PLKO-VERWE) to S/4HANA usage codes (e.g., map local values to 5 – Inspection Plan).
Control KeyMapping of legacy Operation Control Keys (PLPO-STEUS) to target control keys (e.g., to QM01).
Material NumberMapping/normalization of Material numbers (legacy format) to the 18-char S/4 MATNR used in MAPL assignment.
Master Inspection Characteristic (MIC)Mapping of legacy MICs (QPMK/QPMT: VERWMERKM/VERSION) to harmonized MIC IDs in S/4; includes merge rules for duplicates/versions.
Sampling ProcedureMapping of Sampling Procedures (QDSV / QAMV-STICHPRVER) from legacy IDs to target IDs and sampling schemes.
Inspection MethodMapping of Inspection Methods (QMTB/QMTT) from legacy method numbers and versions to target method IDs.
Unit of MeasureMapping of UoM (PLMK-MSEHI, PLPO/PLMK qty fields) to S/4 UoM using T006; includes conversion rules/decimals.
Catalogs / Code Groups / Selected SetsMapping of QM catalogs (defect/characteristic/usage) and selected sets used in plan characteristics to target catalogs/code groups.
Language TextsMapping strategy for short & long texts (header/operation/characteristic) from legacy languages to target language keys (EN + approved translations).
StatusMapping of plan status to S/4 rules (only Released = 4 migrated; others excluded).
SupplierMapping for Supplier from Legacy to S4
CustomerMapping for Customer from Legacy to S/4
Responsible Planner Group or DepartmentMapping of Planner group from Legacy to S/4
Sample-Drawing ProcedureMapping of Sample drawing procedure from Legacy to S/4
Dynamic Modification ruleMapping of Dynamic modification rule from Legacy to S/4

Transformation Dependencies

List the steps that need to occur before transformation can commence
Item #Step DescriptionTeam Responsible

1

Value Mappings are according to the latest design - <List of Value Mappings>

SyWay Data Team


Pre-Load Validation

Project Team

Completeness

TaskAction

Compare Data Counts

  1. Verify row counts between source and target databases.
  2. Identify missing or duplicated records.

Validate the mandatory fields

Validate there is value for all the mandatory fields

Validate Primary Keys and Unique Constraints

  1. Check for duplicate or missing primary key values.
  2. Ensure unique constraints are maintained.

Test Referential Integrity

Confirm dependent records exist in related tables


Accuracy

TaskAction

Validate the transformation

Validate the fields which require transformation have the value after transformation instead of the original field value

Check Data Consistency

  1. Compare field values across systems
  2. Validate data formats and structures

Business

Completeness

TaskAction

Compare Data Count

  1. Verify row counts between source and target databases.
  2. Identify missing or duplicated records.
Review populated templates for missing or incorrect valuesUse checklists to verify completeness and correctness before submission

Accuracy

TaskAction

Conversion Accuracy

Business Data Owner/s to verify that all the data in the load table/file is accurate as per endorsed transformation/ mapping rules (and signed-off DCT data).


Load

The load process includes:

  1. Execute the automated data load into target system using load tool or product the load file if the load must be done manually
  2. Once the data is loaded to the target system, it will be extracted and prepared for Post Load Data Validation

Load Run Sheet

Item #Step DescriptionTeam Responsible

1

Load Scope Definition

- Identify the target system and database structure.

- Define data objects (tables, fields, records) to be loaded.

- Establish business rules for data validation.

Data team

2

Load Methodology

- Specify the loading tools and technologies (Migration Cockpit, LSMW, custom loading program).

Syniti 

3

Data Quality and Validation

- Ensure data integrity checks (null values, duplicates, format validation).

- Perform pre-load validations to verify completeness.

- Define error handling mechanisms for load failures

Syniti 

4

Load Execution Plan

- Establish execution timelines and batch processing schedules.

- Assign responsibilities for monitoring execution.

- Document dependencies on other migration tasks

Syniti

5

Logging and Reporting

- Maintain detailed logs of loading activities.

- Generate summary reports on loaded data volume and quality.

- Define escalation procedures for errors

Syniti 


Load Phase and Dependencies

The Inspection Plan will be loaded in the pre-cutover (PreCutover 4 phase) period.

Before loading, it will have dependency on the following configuration and data objects in the S/4 HANA.

Configuration

Item #Configuration Item
1KNA1 - General Data in Customer Master
2LFA1 - Supplier Master (General Section)
3MARA - General Material Data
4TCA01 - Task list types
5T001W - Plants/Branches
6T006 - Units of Measurement
7TQ39A - Definition of dynamic modification level
8QDDR - Dynamic modification rule (header)
9QPRVK - Sample-drawing procedure
10T412 - Task list status
11T002 - Language Keys (Component BC-I18)
12T024A - Planner group
13T411 - Task list usage
14QMTB - Inspection method master record
15QPMK - Inspection characteristic master
16CSLA - Activity master
17T430 - Operation/Activity control key
18T001W - Plants/Branches
19TQ15 - Inspection catalog type index
20TQ07 - Follow-Up Action for Usage Decision of Inspection Lot
21TQ06 - Procedure for Calculating the Quality Score
22T006 - Units of Measurement
23TQ29A - Dependency tolerance key - nominal measurement
24QPMK - Inspection characteristic master
25QMTB - Inspection method master record
26CRHD - Work Center Header
27T430 - Operation/Activity control key
28T024 - Purchasing Groups
29TQ31 - Inspection Lot Origins

Conversion Objects

Object #Preceding Object Conversion Approach
1043Inspection methods (Inspection methods must exist before assignment to plan)
1056Resources / Work Centers (needed for operations in the Inspection Plan)
1057Master Inspection Characteristics (MICs must exist before assignment to plan)
1064Sampling Procedures (must exist before they can be assigned in plans)
2009Material Master (QM View must exist before Inspection Plan assignment)

Error Handling

Error TypeError DescriptionAction Taken
1Material Master (QM View) does not exist for the plant/material combinationEnsure that the Material Master with QM View is created and valid before plan migration
2Work Center not created or inactive in the assigned plantValidate Work Center mapping and create/activate the Work Center if required
3Sampling Procedure assigned in plan does not existEnsure Sampling Procedures are created and mapped correctly before assignment
4Master Inspection Characteristic (MIC) referenced in plan does not exist or is invalidValidate that MICs exist, are active, and correctly mapped before migration
5Invalid or missing Task List Usage in Inspection Plan headerUpdate Usage assignment to valid configuration
6Inspection method referenced in plan does not exist or is invalidValidate that Inspection methods exist, are active, and correctly mapped before migration


Post-Load Validation

Project Team

Completeness

TaskAction

Validate Record count in the backend

Validate all tables with prefix “PLKO” has the same records as the loading file

Display Records

Pick up a few random Inspection Plan and run t-code: QP03 to validate the Inspection Plan can be displayed without any error.

Perform Source-to-Target Comparisons

  1. Validate that migrated data matches source records.
  2. Check for discrepancies in numerical values, text fields, and timestamps

Accuracy

TaskAction

Execute Sample Queries and Reports

  1. Run queries to validate business logic.
  2. Generate reports to compare expected vs. actual results

Conduct Post-Migration Reconciliation

Generate reports comparing pre- and post-migration data.


Business

Post-load validation is a critical step in data migration, ensuring that transferred data is accurate, complete, and functional within the target system.

1. Ensuring Data Integrity
After migration, data must be consistent with its original structure. Post-load validation checks for missing records, incorrect mappings, and formatting errors to prevent discrepancies.
2. Business Continuity
Faulty data can disrupt operations, leading to financial losses and inefficiencies. Validating post-load data ensures that applications function as expected, preventing downtime.
3. Error Detection and Resolution
By validating data post-migration, businesses can detect anomalies early, reducing the cost and effort required for corrections


Completeness

TaskAction
Perform Source-to-Target Comparisons
  1. Validate that migrated data matches source records.
  2. Check for discrepancies in numerical values, text fields, and timestamps
Conduct Post-Migration ReconciliationGo through reports comparing pre- and post-migration data.

Accuracy

TaskAction

Perform Manual Testing

Conduct manual spot-checks for additional assurance.


Key Assumptions

  • Master Data Standard is up to date as on the date of documenting this conversion approach and data load.
  • Inspection Plan is in scope based on data design and any exception requested by business.
  • Data cleansing has met the required percentage threshold for the specified mock cycle and all preparation activities have been completed.
  • Data entries in DCT are target-ready data unless a specific transformation rule is stated for that field in the transformation rules.


See also


Change log

Version Published Changed By Comment
CURRENT (v. 38) Feb 24, 2026 11:41 REDDY-ext, Naren Removed the CUI object statement from Purpose
v. 46 Feb 17, 2026 15:15 REDDY-ext, Naren Updated the DCT long text section
v. 45 Feb 17, 2026 09:15 REDDY-ext, Naren Updated DCT section
v. 44 Feb 17, 2026 09:10 REDDY-ext, Naren
v. 43 Feb 12, 2026 15:53 REDDY-ext, Naren Update DCT section : DCT template
v. 42 Nov 28, 2025 14:53 REDDY-ext, Naren Updated the Validation reports link(Post load validation)
v. 41 Nov 27, 2025 11:33 REDDY-ext, Naren Removed STXH-TDLOCK, STXL-TDSPO from transformation rules
v. 40 Nov 17, 2025 03:22 REDDY-ext, Naren Update cleansing rules
v. 39 Nov 17, 2025 02:57 REDDY-ext, Naren Updated the scope of CUI
v. 38 Oct 29, 2025 12:47 REDDY-ext, Naren Updated the relevancy to include PLNTY = Q

Go to Page History

Workflow history

Title Last Updated By Updated Status  
There are no pages at the moment.

  • No labels