General presentation
Objective
To align PC but a developer created IP/DTP delta directly in WBP in the past. It causes that we can't transport another delta DTP/IP to the WBP.
To synchronize the Delta DTP's across all the BW systems (Development/Quality/Production)
Solution DTP:
| Step | WBD | WBQ/WBV/WBP |
|---|---|---|
| 0 | There is no Delta DTP or different ID with WBP (possible to have different ID but same object from transport, need to check version management) | Delta DTP was created directly in WBP ( DTP ID:12301) |
| 1 | 1.1. Run Delta DTP (12301) to clean up the pending delta. | |
| 2 | Create a new Delta DTP (ID 12302) with different filter like 0CALMONTH > 2012 to make the DTP selection different and transport across the systems (Development/Quality/Production). If the same delta selection, transport will be error since we can have 1 delta only. by Urgent Change (UC1). | 2.1. Transport should not have error if the DTP delta selection is different. 2.2. Run DTP (12302) Delta without data transfer to initial the new Delta DTP
2.3. Rename DTP (12301) to obsolete, we should not run it any more |
| 3 | Modify the PC to include new DTP (ID 12302) and transport related process chain (PC) by UC2 To align both DTP and PC | Now we have new delta DTP and all DTP and PC are aligned between WBD vs WBP |
If developer can't transport DTP and PC at the same day on the step 2 and 3, it is required to modify PC directly in WBP first to add the new Delta DTP(12302) to the existing PC before the PC will be executed.
In case, we can't control the time of the transport as well. it is required to change PC manually in WBP first to ensure that next load on PC will be run correctly Delta
Solution IP:
| Step | WBD | WBQ/WBV/WBP |
|---|---|---|
| 0 | There is no Delta IP or different ID with WBP (possible to have different ID but same object from transport, need to check version management) | Delta IP was created directly in WBP ( IP ID:45601) |
| 1 | 1.1. Run Delta IP (45601) to clean up the pending delta. 1.2. Delete initial 1.3. Change IP to full or delete the IP 45601 if you are sure that transport will be OK. | |
| 2 | Create Delta IP (ID 45602) and transport across the systems (Development/Quality/Production) by Urgent Change (UC1). | 2.1. Transport should not have error if the IP delta selection is different. Request to change transport mode to BW mode (inform BW Solvay) 2.2. Run IP (12302) Initial without data transfer 2.3. Run IP (12302) Delta
|
| 3 | Transport related process chain (PC) by UC2 To align both DTP and PC | Now we have new delta DTP and all DTP and PC are aligned between WBD vs WBP |
If developer can't transport IP and PC at the same day, it is required to modify PC directly in WBP first to add the new Delta IP(45602) to the existing PC before the PC will be executed.
In case, we can't control the time of the transport as well. it is required to change PC manually in WBP first to ensure that next load on PC will be run correctly Delta