You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 5 Next »

General presentation

Objective of the application

This application is used to follow:

  • the Quality Results for Shipment 
  • As source of MiniCus or MniTab application 
  • To follow the Limites, Quantitative and qualitative results of the Quality inspections.
  • Statistical ratios and calculations on the quality inspections results

Tool Leader + IT leader of the application: 

Usage information

History

This application has been created in 2006 for Rhodia data (WP1). It was upgraded for Solvay data (PF1) in 2017. At the same time data from both Rhodia and Solvay was consolidated and optimized in a unique multiprovider, and the number of used queries was reduced to keep only those necessary

Roles & Access

Roles and access

List of application role + menu role  and explanation if we have several applications role with specials rules.

Role CodeRole DescriptionExplanation
ZR_RCS_CA_M14QM - Quality ManagementThis role gives access to the Query and Workbooks through role menus.
ZBI_RCS_QM_A02Quality Results Application - End User roleThis role controls access to the application.
ZR_*_CA_P01Analysis company - XXX

Role to control access to data based on the company code, with XXX being the name of the company code. There is a many role as there is company code.

In the new multiproviders created, this role is not relevant.

ZR_*_CA_P02

Analysis - Plant XXX - YYY

Role to control access to data based on the plant, with XXX being the name of the plant, and YYY its description. There is a many role as there is plants.

In the new multiproviders created, the infoobject used for authorization is C_PLANT.

Authorization objects

List of autorisation objects mandatory for the application.

Authorization objectExplanation
ZBI_QMThis object gives global access to objects relevant for authorization yet not relevant for the related multiprovider. This is especially true for the controlling area (CO_AREA)
ZXXXXCAP01This object gives access to the various infoobjects company code related and relevant for authorization, with XXXX being the company code considered.
ZXXXXCAP02This object gives access to the various infoobjects plant related and relevant for authorization, with XXXX being the plant considered.

Dataflow overview

Reporting documentation drive folder:

https://drive.google.com/drive/folders/0B0qn89R0RGdqYkZZOFZyYXlXVkE

Exemple of dataflow overview :

BW I&P - Quality Management (QM) Dataflow

Functional and Technical rules on Workbench + Reporting

Rules & Explanations

Inspection Results

4: ODS_QM09 8ODS_QM07 and ODS_QM08 8ODS_QM07

Transformation done but not used. Only the update rules are used

5: ODSO ODS_QM01 -> ODSO ODS_QM01 and ODSO ODS_QM07 -> ODSO ODS_QM07

Daily loading but few cases. Mostly irrelevant

7: TRSF: DBQM03 -> CRQM06 (Solvay) and TRDF: DBQM04 -> CRQM05 (Rhodia) and TRSF DBQM04 -> CRQM03 and TRSF DBQM03 -> CRQM04 (Solvay)

Difference between historical and current data.

7-a: TRSF: DBQM03 -> CRQM06 (Solvay) and TRDF: DBQM04 -> CRQM05 (Rhodia)

Loading of the inspection lots with a creation date /BIC/C_ENSTEHD greater than current date minus 3 years (ex. current date 16/02/2017 ==> Loading of data from 01/01/2015 and upwards)

7-b: TRSF DBQM04 -> CRQM03 and TRSF DBQM03 -> CRQM04 (Solvay)

Loading of the inspection lots with a creation date /BIC/C_ENSTEHD smaller than current date minus 3 years (ex. current date 16/02/2017 ==> Loading of data older than 01/01/2015)

8: TRSF: DPQM09 -> DBQM04 (Rhodia) and TRSF: DPQM08 -> DBQM03 (Solvay)

  • Deletion od data if results exist (field C_MRMITNI).
  • CO_AREA determination

9: TRSF: DPQM07 -> DBQM03 (Solvay) and TRSF: DPQM08 -> DBQM03 (Solvay) and TRSF: DPQM07 -> DBQM03 (Rhodia) and TRSF: DPQM09 -> DBQM04 (Rhodia)

Mapping of a few fields with the values of QASE, QAMR or QASR, depending on the values of c_semesni (if value is set for QASE), c_secode1 (code QASE), c_srcode1 (Code QASR), C_SRMITNI (if value is set for QAMR)

10: TRSF: IH_QM_2LIS_05_QE1_RCS -> DPQM09 and TRSF: IH_QM_2LIS_05_QE1_SOLVAY -> DPQM08

Determining of the shift work and shift work day

11: TRSF: 2LIS_05_QE1 / Rhodia -> IH_QM_2LIS_05_QE1_RCS and TRSF: 2LIS_05_QE1 Solvay -> IH_QM_2LIS_05_QE1 and TRSF: 2LIS_05_QE1 Solvay -> IH_QM_2LIS_05_QE1 and TRSF: 2LIS_05_QE2 - Solvay -> IH_QM_2LIS_05_QE2

Cleaning of data

Inspection Results for deliveries

1: TRSF: DPSD001 -> DBQM06 (Solvay)

Look up on DSO DBQM03 - DSO QM - Business Layer : Inspection Results (Solvay) using batch number and material number from the deliveries to retrieve QM data. There is also a filter on the "generic inspection lot". Solvay is using some batch to do multiple deliveries. However this generates countless lines which would then be multiplied depending on the lines in DBQM03 (generating at worst more than 5 millions lines). Those generic lot are therefore filtered if the number of lines for a given couple batch / material is more than 30.

2: TRSF: DSO_DLV1 -> DBQM05 (Rhodia)

Look up on DSO DBQM04 - DSO QM - Business Layer : Inspection Results (Rhodia) using batch number and material number from the deliveries to retrieve QM data.

3: ODSO DSO_DLV1 -> ODSO DSO_QMTL

Look up on DSO ODS_QM09 - Inspection Results: Quantitative/Qualitative Data using batch number and material number from the deliveries to retrieve QM data.

6: ODSO DSO_QMTL -> CUBE CUB_QM03

Obsolete

7: TRSF: DBQM05 -> CRQM08 (Rhodia) and TRSF: DBQM05 -> CRQM09 (Rhodia) and TRSF: DBQM06 -> CRQM07 (Solvay) and TRSF: DBQM06 -> CRQM10 (Solvay)

Difference between historical and current data

7-a: TRSF: DBQM06 -> CRQM10 (Solvay) and TRSF: DBQM05 -> CRQM09 (Rhodia)

Loading of the inspection lots with a creation date /BIC/C_ENSTEHD greater than current date minus 2 years (ex. current date 16/02/2017 ==> Loading of data from 01/01/2015 and upwards)

7-b: TRSF: DBQM05 -> CRQM08 (Rhodia) and TRSF: DBQM06 -> CRQM07 (Solvay)

Loading of the inspection lots with a creation date /BIC/C_ENSTEHD smaller than current date minus 2 years (ex. current date 16/02/2017 ==> Loading of data older than 01/01/2015)

Dependencies with other applications

Inspection Results

None

Inspection Results for deliveries

Both DSO DSO_DLV1 and DPSD001 (deliveries) need to be loaded before the upwards dataflow is loaded. This is done through the PC:

      • DPSD001: PC_SD_01
      • DSO_DLV1: PC_SD

 

Data loadings

Info providers and objects loaded

Loading frequency

Main Process Chains

Process ChainCodeComments
META - D - QM - Master ChainPC_QM_00Loading of data in delta mode
META - ADH - QM - Inspection Results InitPC_QM_19

Used to reload data for dataflow QM.

Caution: The loading of the two DSO ODS_QM07 and ODS_QM01 for Rhodia is not included.

TD - ADH - QM - Deletion of Inspection Results dataPC_QM_18Used to delete data in infoproviders
TD - Y - QM - Inspection Results - Historic DataPC_QM_07Updates the infocubes containing historical data for both Solvay and Rhodia Data with the previous year. The infocubes containing the last 5 years of data is emptied and reloaded accordingly.
TD - Y - QM - Qual. Insp. Res. for deliv. - Historic DataPC_QM_17Updates the infocubes containing historical data for both Solvay and Rhodia Data with the previous year. The infocubes containing the last 5 years of data is emptied and reloaded accordingly.

Sub Process Chains

Process ChainCodeComments
MD - D - QM - Textes QMPC_QM_24Loading of the texts for specific QM MD
TD - D - QM - Propagation Layer - SolvayPC_QM_01Used to load Solvay data for the propagation layer for every QM projects
TD - D - QM - PL - Inspection Results (Solvay)PC_QM_12Used to load Solvay data for the propagation layer for Inspection Results
TD - D - QM - Propagation Layer - RhodiaPC_QM_02

Used to load Rhodia data for the propagation layer for every QM projects

(Currently not used)

TD - D - QM - Business Layer - RhodiaPC_QM_03Used to load Rhodia data for the business layer for every QM projects
TD - D - QM - BL - Inspect. Results for Deliveries - RhodiaPC_QM_09Used to load Rhodia data for the business layer for Inspection Results for deliveries
TD - D - QM - BL - Inspection Results - RhodiaPC_QM_08Used to load Rhodia data for the business layer for Inspection Results
TD - D - QM - Business Layer - SolvayPC_QM_04Used to load Solvay data for the business layer for every QM projects
TD - D - QM - BL - Inspect. Results for Deliveries - SolvayPC_QM_10Used to load Solvay data for the business layer for Inspection Results for deliveries
TD - D - QM - BL - Inspection Results - SolvayPC_QM_11Used to load Solvay data for the business layer for Inspection Results
TD - ADH - QM - BL - Insp Res for Del - Rhodia - Init < 2013PC_QM_25Used when loading Rhodia data for project inspection results for deliveries. Given the volumetry generated, it's easier to load the data year by year. This PC loads data depending on the creation date up to 31.12.2012
TD - ADH - QM - BL - Insp Res for Del - Rhodia - Init >=2013PC_QM_26Used when loading Rhodia data for project inspection results for deliveries. Given the volumetry generated, it's easier to load the data year by year. This PC loads data depending on the creation date from 01.01.2013
TD - ADH - QM - BL - Insp Res for Del - Solvay - Init < 2013PC_QM_27Used when loading Solvay data for project inspection results for deliveries. Given the volumetry generated, it's easier to load the data year by year. This PC loads data depending on the creation date up to 31.12.2012
TD - ADH - QM - BL - Insp Res for Del - Solvay - Init >=2013PC_QM_28Used when loading Solvay data for project inspection results for deliveries. Given the volumetry generated, it's easier to load the data year by year. This PC loads data depending on the creation date from 01.01.2013
TD - D - QM - Reporting Layer - RhodiaPC_QM_05Used to load Rhodia data for the reporting layer.
TD - D - QM - RL - Inspect. Results for Deliveries - RhodiaPC_QM_15Used to load Rhodia data for the reporting layer for inspection results for deliveries.
TD - D - QM - RL - Inspection Results - RhodiaPC_QM_13Used to load Rhodia data for the reporting layer for inspection results.
TD - D - QM - Reporting Layer - SolvayPC_QM_06Used to load Solvay data for the reporting layer.
TD - D - QM - RL - Inspect. Results for Deliveries - SolvayPC_QM_14Used to load Solvay data for the reporting layer for inspection results for deliveries.
TD - D - QM - RL - Inspection Results - SolvayPC_QM_16Used to load Solvay data for the reporting layer for inspection results.

Average performance

 

Key FigureEstimation
~ Average Process Chain Runtime 
~ Average nb of rows loaded per load 
~ Total nb of rows loaded (if full) 
~ Average Runtime for 10k lines 

Record Keeping

Reporting

Queries End User Documentation

 

Main queries

Main functionalities

Broadcast

Maintenance

Known bugs

Recurring procedure

Planned Evolution

 


Transformation done but not used. Only the update rules are used

  • No labels