General presentation
Objective
To align PC but a developer created IP/DTP delta directly in WBP in the past. It causes that we can't transport another delta DTP/IP to the WBP.
To synchronize the Delta DTP's across all the BW systems (Development/Quality/Production)
Solution:
| Step | WBD | WBQ/WBV/WBP |
|---|---|---|
| 0 | There is no Delta DTP or different DTP ID with WBP | Delta DTP was created directly in WBP ( DTP ID:12301) |
| 1 | Create Full DTP (ID 12302) and transport across the systems (Development/Quality/Production) by Urgent Change (UC1). | 1. Ensure that all pending delta already send to target if not run Delta DTP (12301) 2. Change DTP (12301) from Delta to Full and rename(Delta loading will broken), check first that you can complete all the steps before next delta coming
3. Change DTP(12302) from Full to Delta 4. Run DTP (12302) with init without data transfer (check again that we don't have the new delta coming, if yes, need to find a way to load such delta to the target) 5. Remove flag init without data transfer Now we will have the new delta with the same WBP as before but by different DTP ID but still not aligned with WBD |
| 2 | Change DTP (ID 12302) from Full to Delta and transport DTP and related process chain (PC) by UC2 To align both DTP and PC |
to add the new Delta DTP(12302) to the existing PC before the PC will be executed. In case, we can't control the time of the transport as well. it is required to change PC manually in WBP first |